Petrochemical Inspection Services

Liquefied Fuels Testing Offer: Diesel Fuel And Gasoline

Motor fuel testing

The purpose of fuel quality monitoring is to ensure the highest fuel quality on all gas station chains. Motor fuel testing services provide brand promotion of gas station chains, boosts brand awareness and effective management system of fuel quality.
Our offer of independent quality control of motor fuel includes:

 

  • sample collection of gasoline, diesel, LPG at gas stations, shore tank cargo storage facilities and during supply in compliance with standards: PN-EN ISO 3170, PN-EN 14275 or PN-EN 4275
  • fast delivery of fuel samples to our accredited laboratory under conditions which prevent from any changes of physico-chemical parameters
  • fuel testing: gasoline, diesel fuel, LPG compliance with the current regulations on the motor fuels quality in our accredited laboratories
  • certificate issuance of tested fuel quality
  • intervention fuel quality monitoring anywhere in the country, comprehensive quality monitoring FQMS
  • consultancy on quality and quantity and motor fuels settlement
  • permission to place information confirming independent motor fuels quality control performed by J.S. Hamilton Poland Sp. z o.o.

 

 

Accreditations

The highest standard of sampling and motor fuels testing facilities confirmed by the accreditation issued by Polish Centre of Accreditation No. AK 011 and AB 079. We assure that our tests are carried out with highest precision and run to required industry standards.

Our offer:

  • Gasoline testing. We provide full rage of testing in cohesion with PN-EN 228:
    • octane number RON (Research)
    • octane number MON (Motor)
    • lead content
    • density at 15°C
    • sulfur content
    • induction period method
    • unwashed (left) and washed (right) gum content of gasoline
    • copper strip corrosion
    • appearance
    • aliphatic compound, olefins, polycyclic aromatic hydrocarbons content
    • benzene content
    • oxygenates and oxygen content
    • vapor pressure
    • PAH content
    • fractional composition
    • vapor lock index
  • Diesel fuel testing. We provide full rage of testing in cohesion with PN-EN 228:
    • cetane number
    • cetane index
    • density at 15°C
    • PAH content
    • sulfur content
    • flash point
    • carbon residue
    • ash content
    • water content
    • contamination content
    • copper strip corrosion
    • fatty acid methyl esters (FAME) content
    • oxidation stability
    • lubricity (HFRR)
    • kinematic viscosity
    • fractional composition
    • cloud point
    • cold filter plugging point (CFPP)
  • Heating oil testing (light and heavy). We provide full rage of testing heating oil testing in cohesion with PN-C-96024:2011 also petroleum products:
    • density
    • calorific value
    • flash point
    • kinematic viscosity
    • fractional composition
    • pour point
    • carbon residue
    • sulfur content
    • water content
    • contamination content
    • ash content
    • oxidation stability
    • lubricity (HFRR)
    • vanadium content
    • carbon content
    • carbon dioxide emission factors
  • Biodiesel B20, B100/FAME, RME
  • Waste oils
    • Identity of impurities in technological and utility installations
  • Biofuels

For companies operating on biocomponents and biofuels J.S. Hamilton Poland Sp. z o.o. offers:

  • lab testing outsourcing. Laboratory performs quality monitoring of the crude oil supplies. Also runs routine checks of the process and provides extensive biofuel quality control. Moreover issues appropriate quality certificates for consumers of biocomponents.
  • lab testing:
    • fatty acid methyl esters (FAME, B100) in cohesion with PN-EN 14214
    • bioethanol
    • rapeseed oil used as fuel
    • glycerin analysis
    • bioheating oil
  • blending evaluation of FAME and diesel blend in compliance with Regulations issued by Ministry of Economy regarding biofuels
  • identification and determination of FAME and diesel blends
  • biocomponents sample collection from tanks, cisterns to quality standards

Ministry of Agriculture and Rural Development authorized our laboratory to conduct quality tests on biocomponents and issue quality certificates (Regulation of the Minister of Economy and Labour of 19 October 2005 regarding biocomponents and quality testing method of biocomponents).
Laboratory also tests glycerin in cohesion with Pharmacopoeian methods.